air particle counter China | air particle counter | air particle counter| Asia air particle counter | low cost air particle counter |air particle counter|air particle counter|

Home   About us   Products   Contact us  Distributors

Air Particle Counter
This air particle counter particle can measure particle in air, with airflow 2.83L/min and 28.3L/min large air flow .

air-particle-counter-chy-001-small-picture.jpg

 

 

CHY-001 large flow particulate counter 1CFM Particle counterDetailed content

Features:

Sampling Volume

28.3L/min (1Cfm)

Test Size

0.3,0.5,1,3,5,10um

Self-purification Time

≤10min

Error of Particle Size

0.5um 5um ≤±30%

Error of Concentration

0.5um ≤±30%

Deflection of Measurement

≤±10%

Communication Interface

RS232

Max Communication Speed

9600BPS

Light Source

Import laser diode(using hour>30000 hours)

Power Source

AC220V±5% 50HZ

Weight

10Kg

Overall Size

450×270×150(L×W×H)mm

Service Environment

Working Environment:15~35℃, 10-85%RH

 

Adjustment Standard

Storage Environment:-10~50℃, 10-85%RH

GB/T6167-2007 and particulate counter performance test standard

 Clean Class Estimate Standard

JJF-1190-2008 particulate counter standard

ISO14644 FS209E , New GMP(dynamic/static)

Functions

Sampling Period

1~99s user set

Sampling Delay

≤99s

Test Interval

≤999s

Sampling Type

Singleness、≤99times(set)、continuous

Data Storage

1000 Record

Sampling Location

1000 Group

Counting Type

Cumulative count, fig2.open-window

Alarm Class

Class100 ~ Class300,000 class(FED209E Standard)

Or 5 ~ 9level(ISO14464-1Standard)

Display Type

LCD big screen

Print Type

Built-in temperature-sensitive printer

Display

LCD display,Slope interface,convenient for detecting

Press Key

Functional module interface,fast into detectiong system

Test Stardard

GB/T6167-2007 JJF1190-2008

Clean Class Estimate Standard

ISO14644 FS209E

Standard Accessories

Built-in reset filter,isokinetic samping probe,tripod,portable protection case,operation instruction,adjust report,printer.

Optional Accessories

External humiture sensor,Data analysis software optical disk and data line.

Sevice Environment:
Normal atmosphere, No stange magnetic field
Power Source:A.C220V
±5% 50HZ

Standard Accessories:
1
.Isokinetic sampling ,imported anti-static sampling tube,tripod;
2. Self-purification filter
;
3
,Temperature-sensitive printing paper 2 pcs
4. Printer
5
,Factory calibration report,packing list,operation instruction;

Optional Accessories
1. Data analysis software
2. Humiture sensor
3. Data line

handheld-air-particle-counter-chy002-small-picture.jpg

CHY002  handheld air particle counter

Features:
Using import semiconductor laser tube and import semiconductor photosensitive tube,assure sensitivity and response speed.
Using import micropump
,assure samping volume steady,reduce noise.
The key component-light scattering sensor obviously eliminate intracorporal stray light,improve SNR, test result more precise and reliable.The light scattering sensor got Chinese patent.
Confidence meansurement of this instrument
,According to GB/T6167-2007 Standard,realize auto estimate clean class,creatively to auto estimate ≤9 location points clean class.
1000 records stored,free to check previous data.User can optional PC data analysis sofeware,realize data managerment.
User can chose humiture sensor(optional accessories).
Samping volume display as digit,more intuitive and precise.
“Measurement Number”function
,realize multipoint managerment.
Lithium battery
,more safety,continuous working 6 hours.

Meets JJF-1190-2008 particulate counter standard
Self-purification time≤10min
Deflection of measurement≤±10%
Error of particulate size 0.5um 5um≤±30%
Error of concentration 0.5um≤±30%
Samping volume and error
:2.83L/min ≤±5%
Range of size channel
:0.3,0.5,1,3,5,10um,6 channels,0.3um SNR≥2.5:1
Max concentration
:≤300,000/L
Power DC7.2V
,1800mAh.

Performance parameter:

Particle Size

0.3, 0.5,1,3,5,10μm

Light Source

Laser diode(using hour>30000 hours)

Flow

2.83 L /min(0.1cfm)

Counting Rate

50±10%@0.3μm, 100±10%@0.5μm

Deflection of Measurement

≤±10%

Samping Time

User set (1~99min)

Samping Delay

User set (1~99min)

Samping Rate

1~99times or continuous

Alarm Class

Class10~ Class300,000 class(FED209E Standard)or 2~ 9class (ISO14464-1 standard)

Test Type

Singleness/Repeat/Continuous/Timing/Average

Data Storage

1000 records

Error Indicator

Exceed storage,laser died,exceed adjusted flow(>±5%),battery died

Communication Interface

USB、RS232

Max Communication Speed

12MBPS

Charging Time

3hours,first time 12hours

Self-purification

≤10min

Concentration limit

"+/-5% at 2000000 particles/ft3 (71000 Particle/L)

Display Type

LCD big screen

Print Type

External printer,Epson ribbon

Sampling Location

1000 group

Counting Type

Cumulative counting,region

Power Source

Chargeable Ni-MH battery(6V/2500mAH)or AC adapter(input 100~240V)

Battery working hour

Continuous working > 6 hours

Overall Size

125*43*230mm

Weight

0.98kg

Environmental Conditions

Working Environment: 15~35℃, 10-85%RH;Storage Environment:-10~50℃, 10-85%RH

Standard Accessories

AC adapter,battery charge,reset filter,isokinetic sampling probe,tripod,portable protection case,operation instruction,adjust report,printer

Optional Accessories

External humiture sensor,Data analysis software optical disk and dataline

Test Standard

JIS-B-9921(1997), ASTM-F649-01, ASTM-F328-98 (NIST traceable) JJG547-1988 GB/T6167-2007 JJF1190-2008

UCL Estimate Sandard

ISO14644 FS209E

 

air-particle-counter-lcd-display-chy002-small-picture.jpg

CHY002 WITH LCD particle counter

Summarize:
Using imported semiconductor laser and photosensitive tube;
The key component-light scattering sensor obviously eliminate intracorporal stray light,improve SNR, test result more precise and reliable.The light scattering sensor obtained Chinese patent.
Confidence meansurement of this instrument
,meet GB/T6167-2007 and JJG547-88 Standard,realize auto estimate clean class.
600 records stored,free to check previous data.PC communication interface.
Humiture sensor interface, connect with (optional accessories )humiture sensor can test humiture.
Features
:

Style

CHY002 Laser big screen

Standard

JJF1190-2008

Air volume

2.83 L /min(0.1cfm)

Size channels

0.3, 0.5,1,3,5,10μm

Error of particle size

≤±30%

Error of concentration

≤±30%

Repeatability

≤±10%

Self-purification time

≤10min

Light source

Laser diode(Using hour>30000hours)

Power source

AC 220V 50Hz

Weight

3.6kg

Overall size

270*210*120mm

Service environment

Working environment:15~35℃, 10-85%RH

Store environment:-10~50℃, 10-85%RH

Clean Class estimate Standard

ISO14644 FS209E


Functions

Style

CHY002 Laster big screen

Sampling type

1~991~99 times or continuous

Working time

Continuous working 6 hours

Data storage

600 records

Counting type

Cumulative count, fig2.open-window

Alarm class

1 ~ 100,000 class(FED209E Standard)

Or 2~ 9class (ISO14464-1 Standard)

Display type

LCD big screen

Print

Built-in printer

Error indicator

Exceed Max record,Laser died,

Exceed adjust flow(>±5%)。

Test standard

GB/T6167-2007 JJF1190-2008

Clean Class estimate Standard

ISO14644 FS209E

Standard accessories

Power line,reset filter,

Isokinetic sampling probe,tripod,portable protection case,

Operater instruction,adjust report, printer

Optional accessories

N/A

air-particle-counter-led-display-chy002-small-picture.jpg

 

 

CHY002 WITH LED particle counter

Features:(Meet JJF1190-2008 particle counter standard)

1.      Self-purification: ≤10min

2.       Repeatability:≤±10%FS

3.       Error of particle size:≤±30%

4.      Error of particle concentration:≤±30%

5.       Error of air volume:2.83L/Min≤±5%

6.      Safety:Insulation Resistance>20M (Normal atmosphere)

Other parameter:

1.      Power source:220VAC±10%50HZ

2.       Max particle concentration:≤300,000/2.83L

3.      Size channels:0.0.10(um)

4.       Range of purification class:100~300000 Class

5.        Overall Size:270×210×120mm (L×W×H)

6.       Weight:3.5KG

Environmental Conditions:

1.      Temperture:5℃—35℃

2.      Humidity:RH≤75%

3.      Normal atmosphere,cleanroom

  Others
1. Built-in printer
,auto-printer test report.
2. Instruction,certification of inspection,Test report,guarantee card,tripod,printing paper,easy to use.Aluminium alloy package,portable,detachable-retractable measuring tube.

air-particle-counter-chy003-small-picture.jpg

CHY003 stainless AC.DC particle counter

Summarize:
1.Using imported semiconductor laser and photosensitive tube,assure sensitivity and response speed.using imported micropump,assure flow steady.
2.The key component-light scattering sensor obviously eliminate intracorporal stray light,improve SNR, test result more precise and reliable.
3.Confidence meansurement of this instrument is the only one in China meet GB/T16292-194896, realize auto estimate clean class.
4.1000 records can be stored,free to check previous data.PC communication interface.
5.Humiture sensor interface,connect with (optional accessories )humiture sensor can test humiture.
6.AC/DC power,bulit-in battery and rechargeable,working continuously 6 hours.
7.Stainless steel,LCD display,smart,light,beautiful,portable,long-service time
8.Our company using American Royco’s particle counter adjust device and Duk’s standard particle,assure each product got strict inspection before leave factory,quality is guaranteed.

Service Environment:

Particle concentration limit 400,000/L
Normal atmosphere No strong magnetic field
Power source:A.C220V±5% 50HZ

Features:

Size channels

0.3, 0.5,1,3,5,10μm

Light source

Laser diode(using hour>30000hours)

Flow

2.83 L /Min(0.1cfm)

Deflection of measurement

≤±10%

Error of particle size

0.5um 5um≤±30%

Error of concentration

0.5um≤±30%

Sampling time

User set (1~99min)

Sampling delay

User set (1~99min)

Sampling rate

1~99 times or continuous

Alarm class

Class100 ~ Class300,000(FED209E Standard)or 5 ~ 9(ISO14464-1)

Test type

Singleness/Repeat/Continuous/Timing/Average

Data storage

1000 records

Error indicator

Exceed storage,laser died,exceed adjusted flow(>±5%),battery died

Communication interface

USB、RS232

Max communication speed

12MBPS

Charging time

3hours,first time 12hours

Self-purification time

≤10min

Concentration limit

"+/-5% at 2000000 particles/ft3 (71000 Particle/L)

Display

LCD big screen

Print

Built-in printer,Epson ribbon

Sampling location

1000 group

Counting type

Cumulative counting,region

Power source

Rechargeable lithium battery(7.4V/5200mAH)or AC adapter(100~240V)

Battery working time

Continuous working> 6 hours

Overall size

220*285*140mm

Weight

3.6kg


Rinch Industrial Co.,Limited

Address: Room302, Bldg 17, No. 35 Dedu road, Baoshan, Shanghai China  Zip code: 200941

 Tel: 86-21-36300944 Fax:86-21-36300944  email: goodluckvon@hotmail.com

air particle counter